Environmental Science & Engineering - www.esemag.com - November 2005
Comments? send them to the editor.
Secondary containment lining system for fuel storage
When underground tanks
need to be replaced but
site conditions make
removal and replacement
very costly and difficult, then owners
can retrofit their tanks with a new,
cost-effective, corrosion resistant, secondary
contained lining system.
This is a manufactured on-site,
internal fiberglass system that allows
one to upgrade in-service steel or
fiberglass single wall tanks to a secondary
contained lining system. The
surrounding area and equipment are
left undisturbed as the tank retrofit is
completed without removing the tanks
from the ground. A brand new secondary
contained fiberglass lining system
is manufactured on site by trained and
certified installers.
The new Lifeliner lining system
gives more than twice the protection of
a single wall tank. Two new corrosion
resistant layers are applied using a
three dimensional glass fabric, cured
with a thermosetting resin, using a proprietary
curing system, to create an
interstitial space “sandwich” laminate.
The primary layer contains the
product. The annular space between
the new inner and outer layers provides
continuous leak detection. If there
were a breach of the primary layer, the
product would be contained by the secondary
layer and prevent a leak to the
environment.
Structural Integrity
Unlike some other tank lining
approaches, this system is custom
manufactured on site with the fiberglass
layers bonded to the existing
walls of each tank. This eliminates differential
forces within the converted
tanks. The independent structural
integrity of the new system enables
installation within an in-service, steel
or fiberglass tank. To ensure the
integrity of the system, an air tightness
test of 35KPa is applied to the interstitial
space.
The Lifeliner system has several
advantages:
- Manufactured in accordance with
ULC/ORD-C-58.4 ( Double containment
fibre reinforced plastic linings
for flammable and combustible liquid
storage tanks).
- Manufactured with corrosion resistant
materials, it provides long-term
rust-proof, corrosion-free service.
- The new structure will not be affected
by the future corrosion of the original
tank.
- Proven compatibility with all existing
petroleum products, alcohol blended
fuels and a variety of chemicals.
- Fiberglass gives proven permeation
protection, corrosion and chemical
resistance and structural performance.
- The new lining system does not
depend on the structure of an existing
tank for structural integrity.
Benefits of the system are:
- Converts single wall steel or fiberglass
tanks to a secondary contained
lining system.
- Minimizes site disruption and down
time.
- Eliminates costly excavation and
replacement of existing tanks.
- Conforms to existing steel and fiberglass
tanks.
- Capable of monitoring the tanks’
integrity using hydrostatic, air pressure,
vacuum, or dry sensor monitoring
of annular space.
- 30 year warranty guarantees longterm
protection.
- Provides future access with newly
installed manway. Optional collar and
turbine enclosure will allow easier
access to the piping and its maintenance.
- Manufactured on site by trained and
certified installers ensuring quality
workmanship.
Typical applications
Applications for the Lifeliner lining
system include:
- Retail service stations.
- Fleet fuelling locations.
- Bulk plants with underground tanks.
- Office buildings.
- Chemical plants.
The new system conforms to government
guidelines for secondary containment.
Contact: Richard Murphy of ZCL
Composites Inc.
e-mail: richard.murphy@zcl.com
See our home page on how to order your subscription. We regret we can
only accept orders from Canada.